Signal Conditioner Series

< >

Intelligent digital display table

The output analog 0 to 20 ma, 4-20 ma, 0 to 5 v, 0 to 10 v can choose and buy Optional RS485 interface communication with the computer Can be reported to the police point two/four o 'clock of choose and buy, can set the HI - LO Arbitrary point zero zero (optional buttons)

Download

Display - 19999 to 69999

Input voltage: 0...10 V,Current:(0) 4...20 mA, potentiometer (displacement sensor resistance)

According to the refresh rate  2.5 Times/SEC.(standard),10 times/SEC (Choose)

Accuracy ±0,1 %FS+1count@23°C±3°C

Level of protection IP 65 (Front panel)

working power supply 220 VAC,DC (Choose)

operating temperature -10...+55°C

alarm point   Reported to the police two/four o 'clock(HI,LO Can be set up)(Choose)

Reported to the police on breath jewels relay,250V 3A(standard),light coupling (choose),Solid state relay (choose)

Computer interface RS232/RS 485(Choose)

Slope detection (choose) double displacement sensor input, show difference

Size W 96 x H 48 x D 110 mm

Conform to the hole size DIN 92 x 44 mm

Special programming functions (choose) please contact the sales

AE Series digital display table size chart:

AE Series digital display table wiring diagram: (this figure is for reference only, the actual product shall prevail)

AE Series digital display table selection:

Note: Reported to the police point value can be set only positive (standard); Reported to the police point value can be set to a negative value (to buy)


Note: Arbitrary point reset function relationship with the relay setting () reported to the police point (if in doubt, please contact technical support department before ordering)

1."Reset fixed" also known as the "absolute zero" (standard)

When in a certain position after reset, the new quote p point the location of the value of S1, S2, S3, S4 value minus zero point displacement; Relative to the absolute zero, the value remains the same

2.On the "reset" also known as the "reset" (to buy)

When in a certain position after reset, the new quote p point the location of the value of S1, S2, S3, S4 value remains the same; Relative to the display zero, value the same


Notice: for the convenience of customers to use, since January 1, 2012, all models with relay output, the default factory reset process will be changed to "reset servo".


AE Series digital display table operation instruction to download>>>>>


AE Communication protocol>>>>>  (communication test MODSCAN32 software can be used)