VOLFA Position Sensor
Slide type linear position sensor
Slide type linear position sensor: LWZ-A1 / V1 / V2 Measure length: 0 ... 100mm ... 1500mm Linearity accuracy: ± 0.3% MB Signal output: 4 ... 20mA, 0 ... 10V, 0 ... 5V
DownloadMeasure stroke: 0 ... 100mm ... 1500mm
Linearity accuracy: ± 0.3% MB
Signal output: 4 ... 20mA, 0 ... 10V, 0 ... 5V
LWZ-A1/V1/V2 |
0`
|
75
|
100
|
130
|
150
|
175
|
200
|
225
|
250
|
275
|
300
|
350
|
375
|
400
|
Electrical travel |
mm
|
76
|
102
|
132
|
152
|
177
|
202
|
229
|
254
|
279
|
305
|
355
|
381
|
405
|
Effective electrical travel |
mm
|
75
|
100
|
130
|
150
|
175
|
200
|
226
|
253
|
276
|
302
|
352
|
378
|
403
|
Mechanical stroke |
mm
|
79
|
104
|
135
|
155
|
179
|
204
|
231
|
256
|
281
|
307
|
357
|
384
|
404
|
Operating Voltage |
|
12~24V DC
|
||||||||||||
Output |
|
0-10 V(V1),0-5 V(V2),4-20 mA(A1)
|
||||||||||||
Linearity |
%
|
0.3
|
||||||||||||
Resolution |
|
Infinite
|
||||||||||||
Operating temperature |
°C
|
-10 to +80
|
||||||||||||
Degree of protection |
IP
|
IP50
|
||||||||||||
Operating force |
N
|
less than1.2N
|
||||||||||||
Power |
W
|
2W - 10W
|
||||||||||||
Maximum voltage |
V
|
30V DC
|
||||||||||||
Life |
One hundred million times
|
|||||||||||||
Shock |
G
|
IEC 68-2-6:1982 10G
|
||||||||||||
Shock |
G
|
IEC 68-2-29:1968 40G
|
||||||||||||
Size A |
mm
|
216
|
241
|
271
|
292
|
317
|
343 | 368 | 393 | 418 | 444 | 494 | 521 | 538 |
LWZ-A1/V1/V2 |
0`
|
425
|
450
|
500
|
550
|
600
|
650
|
700
|
750
|
800
|
900
|
1000
|
Electrical travel |
mm
|
430
|
457
|
507
|
557
|
610
|
660
|
710
|
762
|
812
|
914
|
1014
|
Effective electrical travel |
mm
|
428
|
455
|
505
|
555
|
607
|
657
|
707
|
759
|
809
|
912
|
1012
|
Mechanical stroke |
mm
|
430
|
460
|
506
|
558
|
612
|
662
|
712
|
765
|
815
|
917
|
1017
|
Operating Voltage |
|
12~24V DC
|
||||||||||
Output |
|
0-10 V(V1),0-5 V(V2),4-20 mA(A1)
|
||||||||||
Linearity |
%
|
0.3
|
||||||||||
Resolution |
|
Infinite
|
||||||||||
Operating temperature |
°C
|
-10 to +80
|
||||||||||
Degree of protection |
IP
|
IP50
|
||||||||||
Operating force |
N
|
less than 1.2N
|
||||||||||
Power |
W
|
2W - 10W
|
||||||||||
Maximum voltage |
V
|
30V DC
|
||||||||||
Life |
One hundred million times
|
|||||||||||
Shock |
G
|
IEC 68-2-6:1982 10G
|
||||||||||
Impact |
G
|
IEC 68-2-29:1968 40G
|
||||||||||
Size A |
mm
|
563
|
597
|
638
|
688
|
738
|
788
|
838
|
888
|
938
|
1038
|
1138
|
Customized Options (Voltage Output):
1. Output 0-5V DC or 0-10V DC
2. Three-wire (terminal 1: power +, terminal 2: output +, terminal 3: common)
3. Four-wire (terminal 1: power +, terminal 2: output +, terminal 3: output -, terminal 4: power supply -)
Customized Options (Current Output 4-20mA):
1. Two-wire (terminal 1: output +, terminal 2: input +)
2. Three-wire (terminal 1: power +, terminal 2: output +, terminal 3: common)
3. Four-wire (terminal 1: power +, terminal 2: output +, terminal 3: output -, terminal 4: power supply -)